PNG  IHDRPM pHYs+IDATxoHǿqPKa4DTEHhň"1 HJlIуDlȐ%K4FFX2$p~n߯wy}}^npft{=01@=`bzjRRRBXÃňWpI)?+F%!G++Ao^wj71@=`bz&L P01@=`bz&L P01@=`bz&L P01@=`bz&L P01@=`bz&L P01@=`bz19Q^^ɓr1 t:Ą8@EbD+EVOy_ y*b\zjtUU^VTT477NE7 nrwy}\<IH>ʯW^Z!(((BV86 3 ٹp8VVV~呸%JeSvB.W^ZӧOf9 J " 7>.KC$Wy$NW[I/\_N^zqxxX_xǏ bpb\|Y'L^_QIdN\_\Y=YjgP~-Ȋr}uaat/sss=|tH2qNNB( +߾}3 Ԡ0Lv+,;==޽!D",~I8+n8)q'#$9ǍňWpI)?+F%!G++Ao^wj슉o&r lL PORxppǏ-熆}~Q춶6z,,//OOO7L߿׷ܹs'O*J0q ?ZZZFٳرcfymmOD"URt2 x^o(;::=O}}}ffYJJR9{aNNθMnk8Y[JDQ/ ZgΟ?G⎎6 1Ąn_[[xll !v%]Ѩht\JUUUKK 9K!Ziq\OOOiiij8m*"&ۉ:ejjj]]E aH$¿}dFCCCeee `0/*v!+ HZ]]ˋ[5-YeM+ w!☞t`0(erV"IA(Loܸ˗F^"kKV)ic_JVVƆ8jPh.]2Ljkk[__Gedd7o|r~~ݻn;b1BV"IPIzM&ѣG={&8qbxx޽{o޼kKPi׮[ğ?goݺ577700m?"m6t__Hgg'vhhʕ+6-8NјJJ08)p.khhh||v,[__/}z ZxvzNjmll,++SM4IDb***mTR>!,2 (,--,zܹsJfffekaaa$$2MLLl6UY N DV+vkm*%3{lⴴSN b1si :::]3geIv㸹9aZZZ^? B@Ç=== ZYJJR9xtn7͏=|(TOHT'p###`0XV=X$Mq竬4 EIa.kಔ&r)ׯ_gYV~nk8Y[JIa+&rz?1$Iv]y4-IENDB` LED lamp | alerter

Error message

  • Warning: Creating default object from empty value in barcode_generate_image() (line 79 of /home/test/public_html/sites/alerter.eu/modules/barcode/includes/barcode.plugins.inc).
  • An error occured while generating the barcode.

LED lamp

Product name n/a
AC mains connected LED lamp with metal enclosure and edison lamp holder.
Type / model number: 
E14 3W LED Candle
Made in: 
China
Risk: 

The insulation between live primary parts and the accessible metal enclosure is not adequate. The creepage distance between the live parts of the LED module is not sufficient. A user could therefore receive an electric shock from accessible live parts. The product does not comply with the requirements of the Low Voltage Directive nor with European standard EN 62560.

Measures: 

Compulsory measure: Distributor > Ban on the marketing of the product and any accompanying measures
Starting date: 07/08/2023
Voluntary measure: Distributor > Recall of the product from end users
Starting date: 07/08/2023

Alert report: